Model No.: WT-093
Brand: WEITIAN
Radar front-end integrators in every major market hit the same mechanical reality: their WR19 transmit chain must hand over to a WR15 antenna or test port, and the joint between the two bands becomes the weakest point in an otherwise clean RF path. A generic transition shimmed by hand delivers unpredictable alignment, so insertion loss varies unit to unit and calibration eats hours that should have gone to production. Our adapter is machined as a single Gold Plated Copper V Band Waveguide Transition with pinned flange alignment, giving a repeatable path across the 50–60 GHz overlap. It performs equally well as a V Band Waveguide Adapter for Heating Equipment, where laboratory microwave sintering and plasma rigs need a low-reflection feed transition, and as a Waveguide Transition for Radar RF System builds where phase stability across the band matters more than raw bandwidth.
| Item | Specification |
|---|---|
| Band & Flange Interface | WR19 (40–60 GHz) to WR15 (50–75 GHz), UG-383/U to UG-385/U round flanges, pinned alignment |
| Body Material & Plating | OFHC copper body, machined to Ra 0.8 μm bore finish; 1.5 μm nickel strike plus 2.5 μm gold plating |
| Electrical Performance | Insertion loss ≤0.15 dB across 50–60 GHz, return loss ≥21 dB both ports, VSWR ≤1.15 |
| Mechanical Accuracy | 30 mm overall length, flange flatness ≤0.02 mm, bore-to-flange perpendicularity ≤0.03 mm |
| Power & Environment | 10 W continuous wave, -40°C to +85°C, O-ring groove for pressurised line sealing |
| Compliance & Terms | RoHS compliant, 100% swept VNA test with per-unit s-parameter file; 50-piece MOQ, 15 working days |
| Localized Application Scenario | B2B Buyer Type | Measured Advantage of Our Waveguide Transition |
|---|---|---|
| European mmWave radar and test-bench integration in Germany and the Netherlands, where 60 GHz modules are verified to tight calibration budgets and every unit needs traceable data | Radar front-end OEMs, mmWave test and measurement integrators, EMC laboratory builders | Unit-to-unit insertion loss spread falls from 0.9 dB to 0.25 dB thanks to pinned flanges and controlled bore finish, so calibration routines shorten by roughly 55%; return loss held at ≥21 dB removes the ripple that previously forced a 3-point re-tune per module; the 30 mm length fits existing bench fixtures, and per-unit s-parameter files cut incoming verification from 40 minutes to 15 per adapter batch |
A Bengaluru-based industrial radar manufacturer building 60 GHz level-sensing front ends had been assembling its transmit chain with a locally sourced adapter shimmed by hand. Their production records for two quarters showed unit-to-unit insertion loss spread of 0.9 dB, a 12% rework rate at the calibration station, and average 46 minutes of bench time per module before it passed the gain budget. After switching to our gold plated copper transition across the whole line:
Q1: Can the adapter be supplied with a specific flange bolt pattern instead of the standard round flange?
A: Yes, square and custom patterns are machined to drawing on orders above 200 pieces.
Q2: Do you provide s-parameter data for each unit or only samples?
A: Every unit ships with a swept VNA file; sample-only reporting is also available for prototyping.
Q3: Will the plating survive repeated flange re-mating in a lab environment?
A: The nickel strike under 2.5 μm gold withstands repeated torque cycles; we recommend a 0.3 N·m limit.
Send your flange drawings and the frequency window you actually operate in, and we will return a pair of adapters with full s-parameter files for your bench to compare against the transition you use now. Run both through your existing calibration routine and measure the spread yourself — that is the fastest way to see whether the alignment problem is your fixture or your adapter.